AGA DUAL CONTROL
Model No’s: DC3G
02/16 EINS 516911
For use in USA/Canada
Installation
Guide
PLEASE READ THESE INSTRUCTIONS BEFORE COMMENCING SITE SURVEY
OR INSTALLING THIS APPLIANCE.
IMPORTANT : SAVE INSTRUCTIONS FOR FUTURE REFERENCE
REMEMBER: when replacing a part on this appliance, use only replacement parts
that you can be assured conform to the safety and performance specification that
we require. Do not use reconditioned or copy parts that have not been clearly
authorized by AGA.
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - Installation

1AGA DUAL CONTROLModel No’s: DC3G02/16 EINS 516911For use in USA/CanadaInstallationGuidePLEASE READ THESE INSTRUCTIONS BEFORE COMMENCING SITE SURVEYOR

Page 2 - CONTENTS

10CONNECTION TO THE POWER SUPPLY - AGA DC3GElectric Shock HazardRating Plate is located behind removable plinth, see Fig. 4A, Page 11Electrical Ground

Page 3 - PRODUCT SAFETY

11MAINS CABLE ROUTING - AGA DC3GFig. 4DESN 516643MAINS CABLE FED FROMCONTROL TRAY LEFT OR RIGHT EXIT THROUGH DUCTING DEPENDENT UPON POSITION OF SUPPLY

Page 4 - DELIVERY REQUIREMENTS

12FLUE SYSTEMSEE FIGS. 5, 6, 7, 8 & 9The flue system must be installed in accordance with the federal, state and local codes. Only genuine AGA app

Page 5

13DESN 511052Fig. 7DESN 511053AROUND THE HOUSEUNDER THE CAR PORT, ETC.Minimum siting dimensions for flue terminalsPosition SpacingMinimuminch/mm A Di

Page 6 - INSTALLATION

14Fig. 8DESN 516850

Page 7

15DOWNWARD RUNS UP TO 11 3/4”(300mm) BELOW THE APPLIANCE ARE ALLOWED, PROVIDED ONLY ONE BEND IS USED.DOWNWARD RUNS USING 2 BENDS ARE NOT ALLOWED.MAXIM

Page 8 - NOTE: ANY OVERHEAD FITTED

16WIRING DIAGRAM - AGA DC3G Fig. 10

Page 9

17GAS SUPPLY - U.S. PIPE THREADSNOTE: A MANUAL SHUT-OFF VALVE MUST BE INSTALLED IN AN ACCESSIBLE LOCATION IN THE GAS PIPE EXTERNAL TO THE APPLIANCE FO

Page 10

181. Fit the handrail bracket over the fixing stud located on the top plate. Lock into position by tightening the grub screw nearest the appliance. (

Page 11

193. Once the handrail assembly is located squarely, lock the handrail in position by winding in the grub screws on the underside of each handrail

Page 12 - FLUE SYSTEM

2SECTION PAGEPRODUCT SAFETY 3GENERAL NOTES 4DELIVERY REQUIREMENTS 4GENERAL INSTALLATION REQUIREMENTS 4APPLIANCE DIMENSIONS - AGA DC3G 5TECHNICAL

Page 13

20Fig. 14 DESN 516966Inlet Pressure Testing1. Turn off control knob (A) and turn off electrical supply to range.2. Remove facia by pulling off hotpl

Page 14 - DESN 516850

21CAUTION: BEFORE LIGHTING: ENSURE KNOB (A) IS IN THE OFF POSITION (SEE FIG. 27). ALSO ENSURE GAS SUPPLY TO RANGE IS ON, AND THE GAS SERVICE COCK (C)

Page 15

227. Check the condition of the flame supervision thermocouple tip to ensure it is clean and free of carbon. Heavy heat oxidised tips should mean t

Page 16 - WIRING DIAGRAM - AGA DC3G

23Fig. 15Fig. 17Fig. 19Fig. 16Fig. 18Fig. 20OFF POSITIONIGNITION POSITIONFLAME SUPERVISION BURNER POSITIONMAIN BURNERON POSITIONLOW FIRENORMAL RUNNING

Page 17 - AIR SUPPLY

24CONTENT LIST (LOOSE ITEMS)DESCRIPTION PART NO QTY TICKBAKING OVEN CALIBRATION PLATE AE2M231432 1 ( )OVEN GRID SHELF AE4M211863 3

Page 21 - YEARLY SERVICE

28For further advice or information contact your local AGA AmbassadorWith AGA Marvel’s policy of continuous product improvement, the Company reserves

Page 22 - INSTRUCTIONS

3PRODUCT SAFETYMEANING/DESCRIPTION SIGNIFICATION/DESCRIPTIONSYMBOLWARNING/CAUTIONAn appropriate safety instruction should be followed or caution to a

Page 23

4GENERAL NOTESNOTE: THESE INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH THE RANGE AND THE USER TO RETAIN FOR FUTURE REFERENCE.DELIVERY REQUIREMENTSThe

Page 24 - CONTENT LIST (LOOSE ITEMS)

5APPLIANCE DIMENSIONS - AGA DC3GFig. 1 DESN 516847 ARange DimensionsWhen surveying for a range installation the actual clearance required for the ‘bo

Page 25

6Side ClearancesA 1/8” (3mm) gap is required each side between the range top plate and adjoining work surfaces that may be fitted, this is to allow fo

Page 26

7TilingWhen the range is to stand in a recess or against a wall which is to be tiled, under no circumstances should the tiles overlap the range top pl

Page 27

8NOTE: ANY OVERHEAD FITTED CABINETS MUST NOT EXCEED 13” PROJECTED DEPTH ABOVE THE RANGE.DIM ‘D’ TO BE NOT LESS THAN THE NORMAL WIDTH OF THE RANGE.Fig.

Page 28

9Top Plate Adjustment - AGA DC3 (See Fig. 4)In general, adjustment of the top plate is to be avoided. However minimum use of the top plate adjusters c