AGA TC3 Guide d'installation

Naviguer en ligne ou télécharger Guide d'installation pour Cuisiniers AGA TC3. AGA TC3 Installation guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation
Guide
09/13 EINS 516294
PLEASE READ THESE INSTRUCTIONS BEFORE COMMENCING SITE SURVEY
OR INSTALLING THIS APPLIANCE.
IMPORTANT : SAVE INSTRUCTIONS FOR THE LOCAL INSPECTORS USE
CUSTOMER: KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
REMEMBER: when replacing a part on this appliance, use only replacement parts
that you can be assured conform to the safety and performance specification that
we require. Do not use reconditioned or copy parts that have not been clearly
authorised by AGA.
For use in USA/Canada
AGA TOTAL CONTROL
Model No. - TC3 & TC5
3139291
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Model No. - TC3 & TC5

InstallationGuide09/13 EINS 516294PLEASE READ THESE INSTRUCTIONS BEFORE COMMENCING SITE SURVEYOR INSTALLING THIS APPLIANCE.IMPORTANT : SAVE INSTRUCTIO

Page 2 - CONTENTS

MAINS SUPPLY LOCATION - AGA TC3Fig. 4 DESN 516295THE MAINS SUPPLY CONNECTION AND ISOLATION POINT MUST BE WITHINTHE ZONE SHOWN10RATING LABEL LOCATEDBEH

Page 3 - DELIVERY REQUIREMENTS

MAINS SUPPLY LOCATION - AGA TC5 Fig. 5 DESN 516562MAINS CABLE FED FROM CONTROLTRAY LEFT OR RIGHT EXITTHROUGH DUCTING DEPENDENTUPON POSITION OF SUPPLYS

Page 4

HOTCUPBOARD INSTALLATIONNOTE: The AGA TC5 hotcupboard should arrive with the top plate in a jacked up position. Thisis to allow the complete appliance

Page 5

2. Position the plinth alongside the AGA Total Control leaving no gap between the two plinths (See Fig. 8).Check with a spirit level that the plinth l

Page 6 - INSTALLATION

4. Run a straight edge along the front of the AGA Total Control plinth, to ensure the front face ofboth plinths sit squarely against the straight edge

Page 7 - NOTE: ANY OVERHEAD FITTED

Fig. 12 DESN 5165526. Slide hotcupboard onto plinth until rear tongue bracket engages fully into rear of base slot, (See Fig. 12). Ensure the applianc

Page 8

8. Using the stay rod nut adjusting tool, carefully lower the top plate adjusting nuts until the topplate sits at the required height, making sure tha

Page 9

17HANDRAIL CONNECTION - AGA TC3Fig. 16 DESN 516560Handrail brackets. endcaps and handrails require assembly.Locate endcaps onto handrail, place bracke

Page 10

18Fig. 17MAINS CORD AND WIRING DIAGRAM - AGA TC3

Page 11

19Fig. 18WIRING DIAGRAM - AGA TC5 (HOTCUPBOARD OPTION)COLOUR KEYS/COLLEURSBR - BROWN/MARRONBL - BLUE/BLEUGR - GREEN/VERTOR - ORANGE/ORANGEBK - BLACK/N

Page 12 - HOTCUPBOARD INSTALLATION

SECTION PAGEGENERAL NOTES 3DELIVERY REQUIREMENTS 3GENERAL INSTALLATION REQUIREMENTS 3APPLIANCE DIMENSIONS - AGA TC3 4APPLIANCE DIMENSIONS - AGA TC5 5I

Page 13 - DIFFERENTIAL

20INSTRUCTIONSAttach warning hanger (EGLL516660) located in literature pack, to AGA Total Control handrailwhen installation is complete. Advise custom

Page 17 - HANDRAIL CONNECTION - AGA TC3

24For further advice or information contactyour local AGA SpecialistWith AGA’s policy of continuous productimprovement, the Company reserves the right

Page 18

GENERAL NOTES3NOTE: THESE INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH THE APPLIANCEAND THE USER TO RETAIN FOR FUTURE REFERENCE.Before installation o

Page 19

4APPLIANCE DIMENSIONS - AGA TC3Fig. 1 DESN 516297Cooker DimensionsWhen surveying for a cooker installation the actual clearance required for the ‘body

Page 20 - INSTRUCTIONS

APPLIANCE DIMENSIONS - AGA TC5 5Fig. 2 DESN 516561Cooker DimensionsWhen surveying for a cooker installation the actual clearance required for the ‘bod

Page 21

6INSTALLATIONRange Base or HearthIt is essential that the base or hearth on which the range stands should be level and be capableof supporting the tot

Page 22

7NOTE: ANY OVERHEAD FITTEDCABINETS MUST NOT EXCEED 13”PROJECTED DEPTH ABOVE THERANGE.DIM ‘D’ TO BE NOT LESS THAN THENORMAL WIDTH OF THEAPPLIANCE.Fig.

Page 23

CONNECTION TO THE POWER SUPPLY - AGA TC3Electric Shock HazardRating Plate is located behind removable plinth, see Fig. 4.Electrical Grounding is requi

Page 24

POWER SUPPLY - HOTCUPBOARD (AGA TC5)The hotcupboard attachment requires an independent single phase supply. It has amaximum load of 6 amps, protected