4/01 EINS 511502
Gas Fired Cookers
Tx.’itjw;
Installation Instructions for
Aga Gas Power Vent Fired Range
Models: G.C. P.V. (2 Oven) N.G. and LP.G,
G.E. P.V. (4 Oven)
For U.S. and Candían Markets
NOTE: THESE INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH THE APPLIANCE AND THE USER
TO RETAIN FOR FUTURE REFERENCE.
The Gas fired ranges are delivered unassembled. Before installation can be made, the site is inspected for
suitability by an Authorised Aga Distributor and corrected where necessary to conform with local installation codes
or in the absence of local codes with:
In Canada:
The CAN/CGA-B149 installation codes
In U.S.:
The National Fuel Gas Code ANSI Z223 1-latest edition.
Assembly is undertaken on site by the same Aga Distributor to ensure correct performance and safety.
INSTALLATION
It is essential that the base or hearth on which the range stands should be level and strong enough to support the
weight of the range.
Approximate weights;
Models G.C. - 406kg (9001b)
G.E, -585kg (12901b)
The top face of the hearth must be of non-combustible material for a minimum thickness of 12mm (1/2) and
comply with the current Building Regulations and National Fire Laws,
The location must also provide adequate space for servicing and air circulation around the range.
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - For U.S. and Candían Markets

4/01 EINS 511502Gas Fired CookersTx.’itjw;Installation Instructions for Aga Gas Power Vent Fired Range Models: G.C. P.V. (2 Oven) N.G. and LP.G, G.E.

Page 2 - ELECTRICAL

FIG. 4COMMISSiONiNGLIGHTING THE BURNER - (Fig. 4)CAUTION: NO SMOKING OR NAKED LIGHTSOpen the burner outer door to expose the gas control combination v

Page 3 - VENT SYSTEM

OFF^ ìGNITiONWHITE BLOCK LOW FIREGREEN BAND NORMAL RUNNING6. After 30 minutes, check the burner gas pressure, (i) Turn the gas control knob 2 to PILO

Page 4

p[ug. Turn temperature control knob 2 to the mid position of the green band for normal running.7. On the first lighting or if the cooker has been col

Page 5

PILOT ASSEMBLY

Page 6

YEARLY SERVICEIt is recommended that the range be serviced every 12 months.Arrange with the housholder that the range has been turned OFF the night be

Page 7 - Technical Specification

In the event of a component failure which requires replacement, contact your local Aga distributor who will advise and supply the necessary replacemen

Page 8 - GC PV (2 OVENS)

WALL TILINGIf the cooker is to stand in a reoess or against a wall which is to be tiled, in no circumstances should the tiles overlap the range top pl

Page 9 - LOCATION OF NAME PLATE

VENT SYSTEMProducts of combustion discharge is by a fan powered vent pipe 50mm (2in) diameter which can reach up to 6 metres (19.5ft) in length throug

Page 11

HKlYiMARRON]BL BLUE ^BLEUlR BED iRWaK)BK BUCK iNOIflJw №it“e iBuMJC;0 QRBNGE iOfUkhiGElL iSOUS-miSiON)N NEL/TRfeiNEUTREiLsfeel prisr ii'f

Page 13 - PILOT ASSEMBLY

TERMINAL POSITION1. The range must be installed so that the vent terminal is exposed to the external air and terminal clearance comply with:In U.S.: T

Page 14 - REPLACEMENT PARTS

GC PV (2 OVENS)j:rZj№C!!BZra^—1.Q:KNOCK OUT HOLES FOfi VÎNT PIPEFROm* VIEWwKNOCK ourr HOLÎS FOR VENT PIPEGAS CONNECTION R.H,R.H. ^E VIEWPLAN VIEWA B C

Page 15

GE PV {A OVENS)A B C DE :F GH J K LM N P QR Smm14B7967 851 67941 1314 7561125 39 3 69865 375 48 595116 66LOCATION OF NAME PLATEThe model and serial nu