MANAGING ALARMS An alarm indication may appear in one of the follow-ing cases (the alarm can be cleared by pressingbutton 4 “ON OFF”:- Flue gas temper
N.B.: Method 1 is used to carry out maintenance orto switch off the stove permanently at the end of thecold season. Never switch off the stove while i
END OF SEASONWe advise using up all pellets remaining in the tankin order to prevent condensation from forming andthus clogging and blocking the feede
PROBLEM / CAUSE SOLUTIONProblem Pellets not delivered into burn potCauses * Tank is empty* Flue gas extractor fan is not working* Auger blocked by for
PROBLEM / CAUSE SOLUTIONProblem Pellet loader blockedCauses Poor quality pellets, sawdust included accidentally or pellet stuck and obstructing thefee
FUSION PELLET STOVE TECHNICAL DETAILSMax. fuel consumption per hour kg/h 2.9Maximum input kW 14.4Minimum input kW 4.4Maximum output kW 13.0Minimum out
1TABLE OF CONTENTSPAGENO.1. Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STANDARDS N.B.: The information in this manual is given only as a general guide, and local, national or EC regulationsmust also be complied with.RECOM
ASSEMBLY AND INSTALLATION INSTRUCTIONSN.B. To install the stove, use only authorised andtrained personnel, or contact the dealer.1. Check that the flo
FLUE - VERTICAL EXTERNAL OR INTERNALCHIMNEYThe flue arrangement shown is the best solution forevacuating smoke, even when the ventilator is off(no pow
Where it is necessary to have a horizontal length ofpipe, there must be a minimum positive gradient of3% along its length.Do not run flue pipe in a h
FUELWHAT ARE PELLETS?PELLETS consist of sawdust or real wood scrapsground and pressed into small cylinders about 6mm in diameter and 20-30 mm in lengt
When the room temperature is reached, thestove changes from the working program intoECO mode (pilot flame). ECO mode is the samepower as heat setting
Display Shows ActionUT01 Set the current day. If today is Monday then using buttons 1 & 2 set to DAY 1. If Wednesday, set to DAY 3.UT02 Current