AGA FUSION PELLET STOVE Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Poêles AGA FUSION PELLET STOVE. AGA FUSION PELLET STOVE Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 17
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Operating & Installation Manual
FUSION PELLET STOVE
Vue de la page 0
1 2 3 4 5 6 ... 16 17

Résumé du contenu

Page 1 - FUSION PELLET STOVE

Operating & Installation ManualFUSION PELLET STOVE

Page 2 - TABLE OF CONTENTS

ELECTRONIC CONTROL PANELREMOTE CONTROL FUNCTIONS (optional)9Access to timer-thermostatand clock programmerPower increasefrom 1 to 5Room temperature se

Page 3

CIRCUIT BOARD WIRING DIAGRAM10

Page 4 - STOVE DIMENSIONS (MM)

MANAGING ALARMS An alarm indication may appear in one of the follow-ing cases (the alarm can be cleared by pressingbutton 4 “ON OFF”:- Flue gas temper

Page 5 - Min. 2 meters

N.B.: Method 1 is used to carry out maintenance orto switch off the stove permanently at the end of thecold season. Never switch off the stove while i

Page 6

END OF SEASONWe advise using up all pellets remaining in the tankin order to prevent condensation from forming andthus clogging and blocking the feede

Page 7

PROBLEM / CAUSE SOLUTIONProblem Pellets not delivered into burn potCauses * Tank is empty* Flue gas extractor fan is not working* Auger blocked by for

Page 8

PROBLEM / CAUSE SOLUTIONProblem Pellet loader blockedCauses Poor quality pellets, sawdust included accidentally or pellet stuck and obstructing thefee

Page 9

FUSION PELLET STOVE TECHNICAL DETAILSMax. fuel consumption per hour kg/h 2.9Maximum input kW 14.4Minimum input kW 4.4Maximum output kW 13.0Minimum out

Page 10 - ELECTRONIC CONTROL PANEL

1TABLE OF CONTENTSPAGENO.1. Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 11 - CIRCUIT BOARD WIRING DIAGRAM

STANDARDS N.B.: The information in this manual is given only as a general guide, and local, national or EC regulationsmust also be complied with.RECOM

Page 12 - 2. Push The Button

ASSEMBLY AND INSTALLATION INSTRUCTIONSN.B. To install the stove, use only authorised andtrained personnel, or contact the dealer.1. Check that the flo

Page 13

FLUE - VERTICAL EXTERNAL OR INTERNALCHIMNEYThe flue arrangement shown is the best solution forevacuating smoke, even when the ventilator is off(no pow

Page 14

Where it is necessary to have a horizontal length ofpipe, there must be a minimum positive gradient of3% along its length.Do not run flue pipe in a h

Page 15 - PROBLEMS - CAUSES - SOLUTIONS

FUELWHAT ARE PELLETS?PELLETS consist of sawdust or real wood scrapsground and pressed into small cylinders about 6mm in diameter and 20-30 mm in lengt

Page 16

When the room temperature is reached, thestove changes from the working program intoECO mode (pilot flame). ECO mode is the samepower as heat setting

Page 17 - Rev:00 1 DP 080807

Display Shows ActionUT01 Set the current day. If today is Monday then using buttons 1 & 2 set to DAY 1. If Wednesday, set to DAY 3.UT02 Current

Commentaires sur ces manuels

Pas de commentaire